RA2E1260731011: warmer orange R60/G24, breath valley floor (no pure-red tails), 0.5s off hold / 6.1s cycle; v3 GIFs
第6行: 第6行:


Applies to firmware '''RA2E1260726001''' and later. Earlier firmware did not distinguish system on/off while charging or charged.
Applies to firmware '''RA2E1260726001''' and later. Earlier firmware did not distinguish system on/off while charging or charged.
Since '''RA2E1260731011''' the charging orange is warmer (R60 %/G24 % instead of R55 %/G35 %), the breath fades only to a dim-orange floor (≈1/12 of peak) before the valley off — on earlier firmware the dim ends of each breath cycle could look pure red — and the valley off hold is 0.5 s instead of 0.24 s (cycle ≈6.1 s).


中文版见 [[Photonicat 2 LED 指示灯]]. For buzzer tones see [[Photonicat 2 Sound Guide]].
中文版见 [[Photonicat 2 LED 指示灯]]. For buzzer tones see [[Photonicat 2 Sound Guide]].
第11行: 第13行:
==Quick reference==
==Quick reference==


The animations below are illustrative; their timing matches the firmware (5.84 s breathing cycle, 2 s heartbeat).
The animations below are illustrative; their timing matches the firmware (≈6.1 s breathing cycle, 2 s heartbeat).




第17行: 第19行:
! Animation !! Indicator !! Meaning
! Animation !! Indicator !! Meaning
|-
|-
| [[File:Pcat2-led-orange-breathing-v2.gif|52px|link=]] || 🟠 Yellow, breathing || Charging, system running
| [[File:Pcat2-led-orange-breathing-v3.gif|52px|link=]] || 🟠 Yellow, breathing || Charging, system running
|-
|-
| [[File:Pcat2-led-orange-solid-v2.gif|52px|link=]] || 🟠 Yellow, steady || Charging, system off
| [[File:Pcat2-led-orange-solid-v3.gif|52px|link=]] || 🟠 Yellow, steady || Charging, system off
|-
|-
| [[File:Pcat2-led-green-breathing-v2.gif|52px|link=]] || 🟢 Green, breathing || Fully charged (or at charge limit), system running
| [[File:Pcat2-led-green-breathing-v3.gif|52px|link=]] || 🟢 Green, breathing || Fully charged (or at charge limit), system running
|-
|-
| [[File:Pcat2-led-green-solid-v2.gif|52px|link=]] || 🟢 Green, steady || Fully charged (or at charge limit), system off
| [[File:Pcat2-led-green-solid-v2.gif|52px|link=]] || 🟢 Green, steady || Fully charged (or at charge limit), system off
第39行: 第41行:
! Power level !! Charger !! Animation !! Colour !! Pattern !! Timing
! Power level !! Charger !! Animation !! Colour !! Pattern !! Timing
|-
|-
| Charging, any level || Connected || [[File:Pcat2-led-orange-breathing-v2.gif|44px|link=]] || 🟠 Yellow || Breathing (system on) || 2.8 s up / 2.8 s down / 0.24 s off, ≈5.84 s cycle
| Charging, any level || Connected || [[File:Pcat2-led-orange-breathing-v3.gif|44px|link=]] || 🟠 Yellow || Breathing (system on) || 2.8 s up / 2.8 s down / 0.5 s off, ≈6.1 s cycle; fades to a dim-orange floor (≈peak/12), never pure red
|-
|-
| Charging, any level || Connected || [[File:Pcat2-led-orange-solid-v2.gif|44px|link=]] || 🟠 Yellow || Steady (system off) || Constant
| Charging, any level || Connected || [[File:Pcat2-led-orange-solid-v3.gif|44px|link=]] || 🟠 Yellow || Steady (system off) || Constant
|-
|-
| Full, or at charge limit || Connected || [[File:Pcat2-led-green-breathing-v2.gif|44px|link=]] || 🟢 Green || Breathing (system on) || Same 5.84 s cycle, after 10 s delay
| Full, or at charge limit || Connected || [[File:Pcat2-led-green-breathing-v3.gif|44px|link=]] || 🟢 Green || Breathing (system on) || Same ≈6.1 s cycle, after 10 s delay
|-
|-
| Full, or at charge limit || Connected || [[File:Pcat2-led-green-solid-v2.gif|44px|link=]] || 🟢 Green || Steady (system off) || Constant, after 10 s delay
| Full, or at charge limit || Connected || [[File:Pcat2-led-green-solid-v2.gif|44px|link=]] || 🟢 Green || Steady (system off) || Constant, after 10 s delay
|-
|-
| Below 6600 mV, DC ≥ 8 V, no charge current || Connected || [[File:Pcat2-led-orange-solid-v2.gif|44px|link=]] || 🟠 Yellow || Steady || Constant
| Below 6600 mV, DC ≥ 8 V, no charge current || Connected || [[File:Pcat2-led-orange-solid-v3.gif|44px|link=]] || 🟠 Yellow || Steady || Constant
|-
|-
| Above 6500 mV, system on || None || [[File:Pcat2-led-green-heartbeat-v2.gif|44px|link=]] || 🟢 Green || Heartbeat pulse || 2 s period
| Above 6500 mV, system on || None || [[File:Pcat2-led-green-heartbeat-v2.gif|44px|link=]] || 🟢 Green || Heartbeat pulse || 2 s period
第71行: 第73行:
| Shutting down || [[File:Pcat2-led-green-blink-shutdown-v2.gif|44px|link=]] || 🟢 Green || Blink || ≈0.5 s on / 1.5 s off
| Shutting down || [[File:Pcat2-led-green-blink-shutdown-v2.gif|44px|link=]] || 🟢 Green || Blink || ≈0.5 s on / 1.5 s off
|-
|-
| Firmware download mode || [[File:Pcat2-led-orange-blink-fast-v2.gif|44px|link=]] || 🟠 Yellow || Fast blink || ≈0.5 s period
| Firmware download mode || [[File:Pcat2-led-orange-blink-fast-v3.gif|44px|link=]] || 🟠 Yellow || Fast blink || ≈0.5 s period
|-
|-
| Reset / factory restore mode || [[File:Pcat2-led-orange-blink-slow-v2.gif|44px|link=]] || 🟠 Yellow || Slow blink || ≈1 s period
| Reset / factory restore mode || [[File:Pcat2-led-orange-blink-slow-v3.gif|44px|link=]] || 🟠 Yellow || Slow blink || ≈1 s period
|}
|}


第108行: 第110行:
==Notes==
==Notes==


* Breathing runs at a lower peak brightness (25 % duty) than steady (50 %), so a breathing indicator looks dimmer than a steady one of the same colour.
* Green breathing peaks at 25 % duty while steady green is 50 %, so breathing green looks dimmer than steady green. Orange breathing peaks at the same R60 %/G24 % mix as steady orange.
* 🔴 Red is only ever used for low battery, and keeps flashing until the voltage recovers or a charger is connected.
* 🔴 Red is only ever used for low battery, and keeps flashing until the voltage recovers or a charger is connected.
* The indicator can be disabled entirely through the host protocol, in which case it stays off in all states.
* The indicator can be disabled entirely through the host protocol, in which case it stays off in all states.

2026年7月31日 (五) 19:26的版本

Photonicat 2 has a single two-colour indicator LED (red + green). Yellow/orange is produced by lighting both colours together; there is no blue.

The indicator follows a MacBook-style scheme:

  • Colour tells you the charge state — 🟠 yellow = charging, 🟢 green = charged.
  • Motion tells you the machine state — breathing = system running, steady = system off.

Applies to firmware RA2E1260726001 and later. Earlier firmware did not distinguish system on/off while charging or charged.

Since RA2E1260731011 the charging orange is warmer (R60 %/G24 % instead of R55 %/G35 %), the breath fades only to a dim-orange floor (≈1/12 of peak) before the valley off — on earlier firmware the dim ends of each breath cycle could look pure red — and the valley off hold is 0.5 s instead of 0.24 s (cycle ≈6.1 s).

中文版见 Photonicat 2 LED 指示灯. For buzzer tones see Photonicat 2 Sound Guide.

Quick reference

The animations below are illustrative; their timing matches the firmware (≈6.1 s breathing cycle, 2 s heartbeat).


Animation Indicator Meaning
🟠 Yellow, breathing Charging, system running
🟠 Yellow, steady Charging, system off
🟢 Green, breathing Fully charged (or at charge limit), system running
🟢 Green, steady Fully charged (or at charge limit), system off
🟢 Green, heartbeat pulse Running on battery, charge level normal
🔴 Red, flashing Low battery (below 6500 mV — see Low battery red light)
⚫ Off Idle on battery, system off

Full state table

Battery thresholds are firmware defaults and can be overridden by the host. Values are for the 2S pack: full 8280 mV, low warning 6500 mV, minimum boot 6600 mV, hard shutdown 6300 mV.

Power level Charger Animation Colour Pattern Timing
Charging, any level Connected 🟠 Yellow Breathing (system on) 2.8 s up / 2.8 s down / 0.5 s off, ≈6.1 s cycle; fades to a dim-orange floor (≈peak/12), never pure red
Charging, any level Connected 🟠 Yellow Steady (system off) Constant
Full, or at charge limit Connected 🟢 Green Breathing (system on) Same ≈6.1 s cycle, after 10 s delay
Full, or at charge limit Connected 🟢 Green Steady (system off) Constant, after 10 s delay
Below 6600 mV, DC ≥ 8 V, no charge current Connected 🟠 Yellow Steady Constant
Above 6500 mV, system on None 🟢 Green Heartbeat pulse 2 s period
Above 6500 mV, system starting None 🟢 Green Steady Constant
Above 6600 mV, system off None 🟢 Green Steady Constant
Below 6500 mV, system on None 🔴 Red Continuous flashing 1 s on / 1 s off, begins after 60 s, until the voltage recovers
Below 6500 mV, short press None 🔴 Red Flicker 1 s on / 1 s off, while held or until the voltage recovers
Charger removed, system off None ⚫ Off

Service and transitional states

These override the states above.

State Animation Colour Pattern Timing
Shutting down 🟢 Green Blink ≈0.5 s on / 1.5 s off
Firmware download mode 🟠 Yellow Fast blink ≈0.5 s period
Reset / factory restore mode 🟠 Yellow Slow blink ≈1 s period

Low battery red light

When the battery runs low the indicator turns 🔴 flashing red. This is the only situation in which red is used.

Item Detail
Trigger Battery below 6500 mV (2S pack, about 3.25 V per cell) with no charger connected
Rhythm 1 second on / 1 second off
Repeats Flashes continuously until the voltage recovers or a charger is connected
While running Starts only after the voltage has stayed below the threshold for 60 seconds
Short press With a low battery, a short press of the power button triggers the red flashing immediately (after a 0.5 s debounce)
Effect on green The green heartbeat stops while red is active; the two never show together

⚠️ Important

  • The red warning keeps flashing until the voltage recovers or a charger is connected; it does not stop on its own. (Firmware before RA2E1260726003 flashed only 3 times and then went quiet.)
  • The red threshold (6500 mV) is only 200 mV above the hard shutdown point (6300 mV). That is a very steep part of the 2S li-ion discharge curve, so connect a charger promptly once you see red.
  • The trigger is voltage, not a percentage. Under heavy load the voltage sags and the warning can appear while a useful charge remains; when the load drops the voltage recovers and the warning stops.

Charge limit

If a charge limit is configured (for example 80 %), the charger is switched off once the pack reaches it. Charge current drops to zero, so the device treats this as fully charged and shows 🟢 green. The pack then powers the load and slowly discharges until it falls below the resume threshold, at which point charging restarts and the indicator returns to 🟠 yellow. Each transition is delayed by about 10 seconds.

Notes

  • Green breathing peaks at 25 % duty while steady green is 50 %, so breathing green looks dimmer than steady green. Orange breathing peaks at the same R60 %/G24 % mix as steady orange.
  • 🔴 Red is only ever used for low battery, and keeps flashing until the voltage recovers or a charger is connected.
  • The indicator can be disabled entirely through the host protocol, in which case it stays off in all states.
  • For how the charge level behind these indications is computed, see Photonicat 2 SOC Calculation.