C2h2留言 | 贡献
Add 'Low battery red light' section: 6500 mV trigger, 60 s delay, stops after 3 flashes, and only 200 mV above the 6300 mV shutdown point
第27行: 第27行:
| [[File:Pcat2-led-green-heartbeat-v2.gif|52px|link=]] || 🟢 Green, heartbeat pulse || Running on battery, charge level normal
| [[File:Pcat2-led-green-heartbeat-v2.gif|52px|link=]] || 🟢 Green, heartbeat pulse || Running on battery, charge level normal
|-
|-
| [[File:Pcat2-led-red-lowbatt-v2.gif|52px|link=]] || 🔴 Red, 3 flashes || Low battery
| [[File:Pcat2-led-red-lowbatt-v2.gif|52px|link=]] || 🔴 Red, 3 flashes || Low battery (below 6500 mV, 3 flashes only — see [[#Low battery red light|Low battery red light]])
|-
|-
| [[File:Pcat2-led-off-v2.gif|52px|link=]] || ⚫ Off || Idle on battery, system off
| [[File:Pcat2-led-off-v2.gif|52px|link=]] || ⚫ Off || Idle on battery, system off
第75行: 第75行:
| Reset / factory restore mode || [[File:Pcat2-led-orange-blink-slow-v2.gif|44px|link=]] || 🟠 Yellow || Slow blink || ≈1 s period
| Reset / factory restore mode || [[File:Pcat2-led-orange-blink-slow-v2.gif|44px|link=]] || 🟠 Yellow || Slow blink || ≈1 s period
|}
|}
==Low battery red light==
When the battery runs low the indicator turns 🔴 '''flashing red'''. This is the only situation in which red is used.
{| class="wikitable"
! Item !! Detail
|-
| Trigger || Battery below '''6500 mV''' (2S pack, about 3.25 V per cell) with '''no charger connected'''
|-
| Rhythm || 1 second on / 1 second off
|-
| Repeats || '''Stops after 3 flashes''' — it does not keep flashing
|-
| While running || Starts only after the voltage has stayed below the threshold for '''60 seconds'''
|-
| Short press || With a low battery, a short press of the power button shows it immediately (3 flashes after a 0.5 s debounce)
|-
| Effect on green || The green heartbeat stops while red is active; the two never show together
|}
'''⚠️ Important'''
* The red warning '''stops after 3 flashes'''. If you miss it, there is no further light warning before the device shuts down.
* To check the level again, '''press the power button once''' to re-trigger the warning.
* The red threshold (6500 mV) is only '''200 mV above the hard shutdown point (6300 mV)'''. That is a very steep part of the 2S li-ion discharge curve, so connect a charger promptly once you see red.
* The trigger is '''voltage, not a percentage'''. Under heavy load the voltage sags and the warning can appear while a useful charge remains; when the load drops the voltage recovers and the warning stops.


==Charge limit==
==Charge limit==

2026年7月26日 (日) 11:46的版本

Photonicat 2 has a single two-colour indicator LED (red + green). Yellow/orange is produced by lighting both colours together; there is no blue.

The indicator follows a MacBook-style scheme:

  • Colour tells you the charge state — 🟠 yellow = charging, 🟢 green = charged.
  • Motion tells you the machine state — breathing = system running, steady = system off.

Applies to firmware RA2E1260726001 and later. Earlier firmware did not distinguish system on/off while charging or charged.

中文版见 Photonicat 2 LED 指示灯. For buzzer tones see Photonicat 2 Sound Guide.

Quick reference

The animations below are illustrative; their timing matches the firmware (5.84 s breathing cycle, 2 s heartbeat).


Animation Indicator Meaning
🟠 Yellow, breathing Charging, system running
🟠 Yellow, steady Charging, system off
🟢 Green, breathing Fully charged (or at charge limit), system running
🟢 Green, steady Fully charged (or at charge limit), system off
🟢 Green, heartbeat pulse Running on battery, charge level normal
🔴 Red, 3 flashes Low battery (below 6500 mV, 3 flashes only — see Low battery red light)
⚫ Off Idle on battery, system off

Full state table

Battery thresholds are firmware defaults and can be overridden by the host. Values are for the 2S pack: full 8280 mV, low warning 6500 mV, minimum boot 6600 mV, hard shutdown 6300 mV.

Power level Charger Animation Colour Pattern Timing
Charging, any level Connected 🟠 Yellow Breathing (system on) 2.8 s up / 2.8 s down / 0.24 s off, ≈5.84 s cycle
Charging, any level Connected 🟠 Yellow Steady (system off) Constant
Full, or at charge limit Connected 🟢 Green Breathing (system on) Same 5.84 s cycle, after 10 s delay
Full, or at charge limit Connected 🟢 Green Steady (system off) Constant, after 10 s delay
Below 6600 mV, DC ≥ 8 V, no charge current Connected 🟠 Yellow Steady Constant
Above 6500 mV, system on None 🟢 Green Heartbeat pulse 2 s period
Above 6500 mV, system starting None 🟢 Green Steady Constant
Above 6600 mV, system off None 🟢 Green Steady Constant
Below 6500 mV, system on None 🔴 Red Flicker 1 s on / 1 s off, 3 flashes, begins after 60 s
Below 6500 mV, short press None 🔴 Red Flicker 1 s on / 1 s off, 3 flashes
Charger removed, system off None ⚫ Off

Service and transitional states

These override the states above.

State Animation Colour Pattern Timing
Shutting down 🟢 Green Blink ≈0.5 s on / 1.5 s off
Firmware download mode 🟠 Yellow Fast blink ≈0.5 s period
Reset / factory restore mode 🟠 Yellow Slow blink ≈1 s period

Low battery red light

When the battery runs low the indicator turns 🔴 flashing red. This is the only situation in which red is used.

Item Detail
Trigger Battery below 6500 mV (2S pack, about 3.25 V per cell) with no charger connected
Rhythm 1 second on / 1 second off
Repeats Stops after 3 flashes — it does not keep flashing
While running Starts only after the voltage has stayed below the threshold for 60 seconds
Short press With a low battery, a short press of the power button shows it immediately (3 flashes after a 0.5 s debounce)
Effect on green The green heartbeat stops while red is active; the two never show together

⚠️ Important

  • The red warning stops after 3 flashes. If you miss it, there is no further light warning before the device shuts down.
  • To check the level again, press the power button once to re-trigger the warning.
  • The red threshold (6500 mV) is only 200 mV above the hard shutdown point (6300 mV). That is a very steep part of the 2S li-ion discharge curve, so connect a charger promptly once you see red.
  • The trigger is voltage, not a percentage. Under heavy load the voltage sags and the warning can appear while a useful charge remains; when the load drops the voltage recovers and the warning stops.

Charge limit

If a charge limit is configured (for example 80 %), the charger is switched off once the pack reaches it. Charge current drops to zero, so the device treats this as fully charged and shows 🟢 green. The pack then powers the load and slowly discharges until it falls below the resume threshold, at which point charging restarts and the indicator returns to 🟠 yellow. Each transition is delayed by about 10 seconds.

Notes

  • Breathing runs at a lower peak brightness (25 % duty) than steady (50 %), so a breathing indicator looks dimmer than a steady one of the same colour.
  • 🔴 Red is only ever used for low battery, and stops after three flashes rather than flashing continuously.
  • The indicator can be disabled entirely through the host protocol, in which case it stays off in all states.